Versiones comparadas

Clave

  • Se ha añadido esta línea.
  • Se ha eliminado esta línea.
  • El formato se ha cambiado.

Once the product has been installed using a software component, it is necessary to activate a few BC_SETs that allows to configure the tables used in b+ SII with the necessary data.

...


If, on the other hand, the product is being upgraded to installation by Software Component, the BC_SETs of the applicable versions must be activated:

...

  1. If the product version 1.7.4 has not been previously installed in the system by means of transport orders, activate the BC_SETs of this version: Activation of BC_SETs release 1.7.4
  2. If product version 1.7.5 has not been previously installed in the system via transport orders, activate the BC_SETs of this version: Activation of BC_SETs release 1.7.5
  3. If the product version 1.7.6 has not been previously installed in the system by means of transport orders, activate the BC_SETs of this version: Activation of BC_SETs release 1.7.6
  4. If the product version 1.7.7 has not been previously installed in the system by means of transport orders, activate the BC_SETs of this version: Activation BC_SETs version 1.7.7
  5. If product version 1.7.8 has not been previously installed in the system by means of transport orders, activate the BC_SETs of this version: BC_SETs activation release 1.7.8.
  6. If product version 1.7.9 has not been previously installed in the system by means of transport orders, activate the BC_SETs of this version: Activation of BC_SETs release 1.7.9
  7. If product version 1.7.9.1 has not been previously installed in the system by means of transport orders, activate the BC_SETs of this version: Activation BC_SETs version 1.7.9.1
  8. If version 1.8.0 of the product has not been previously installed in the system through transfer orders, activate the BC_SETs of this version: Activation BC_SETs version 1.8.0.

  9. If version 1.8.1 of the product has not been previously installed in the system through transfer orders, activate the BC_SETs of this version: Activation BC_SETs version 1.8.1.


The order of activation of these BC_SETs will be as quoted in this guide. So the order would be as follows:

  1. /EDGE/SII_BC_SET_SA_SIN_MANDT (if activation is needed)
  2. /EDGE/SII_BC_SET_SA_CON_MANDT (if activation is needed)
  3. /EDGE/SII_BC_SET_SP5_SIN_MANDANT (if activation is needed)
  4. /EDGE/SII_BC_SET_SP5_CON_MANDANT (if activation is needed)
  5. /EDGE/SII_BC_SET_SP6_SIN_MANDANT (if activation is needed)

  6. /EDGE/SII_BC_SET_SP6_CON_MANDANT (if activation is needed)

  7. /EDGE/SIICNC_BC_SET_SP7_CON_MDNT (if activation is needed)

  8. /EDGE/SII_BC_SET_SP7_SIN_MDNT (if activation is needed)

  9. /EDGE/SII_BC_SET_SP7_CON_MDNT (if activation is needed)
  10. /EDGE/SII_BC_SET_SP8_SIN_MDNT (if activation is needed)
  11. /EDGE/SII_BC_SET_SP8_CON_MDNT (if activation is needed)
  12. /EDGE/SII_BC_SET_SP9_SIN_MDNT (if activation is needed)
  13. /EDGE/SII_BC_SET_SP9_CON_MDNT (if activation is needed)
  14. /EDGE/SII_BC_SET_SP10_SIN_MDNT (if activation is needed)
  15. /EDGE/SII_BC_SET_SP10_CON_MDNT (if activation is needed)
  16. /EDGE/SII_BC_SET_SP11_CON_MDNT (if activation is needed)
  17. /EDGE/SII_BC_SET_SP12_CON_MDNT 
  18. /EDGE/SII_BC_SET_SP13_SIN_MDNT 
  19. /EDGE/SII_BC_SET_SP13_CON_MDNT

Before activating them, you need to configure the SCPRSTAM table. This table is independent of the client, so it does not matter in which client to configure it. It is only set for one client.

...

In this table you have to enter entries for the following tables:

    • EDOCOUNTRYTCH
    • EDOFILETYPE
    • EDOFILETYPEV
    • EDOFILETYPET
    • EDOSRCTYPE
    • EDOSRCTYPET
    • TBE31
    • TMENU01
    • TTREES
    • TVIMF
    • /EDGE/SII_PAR_MW
    • /EDGE/SII_CS001
    • /EDGE/SII_CS002
    • /EDGE/SII_MP_000
    • /EDGE/SII_MP_005
    • /EDGE/SII_PRIORI
    • /EDGE/SII_MPT014
    • /EDGE/SII_MP_014
    • /EDGE/SII_VAL_01
    • /EDGE/SII_CO_015
    • /EDGE/SII_MPT010
    • /EDGE/SII_MP_010
    • /EDGE/SII_MIDDLE
    • /EDGE/SII_INTERM
    • /EDGE/SIITINTERM
    • /EDGE/SII_PRO_SR

Activation example for a BC_SET

To activate a BC_SET go to t-code SCPR20. Enter the name of BC_SET: /EDGE/SII_BC_SET_SP5_SIN_MANDANT.

Click on the  Image Modified Consistency Check icon and check that no errors occur.


This warning may appear:

  • Field TABNAME of set CE /EDGE/SII_BC_SET_SP5_SIN_MANDANT is not an integral part of table/view EDOTYPE.
  • Field REF_PROCESS of set CE /EDGE/SII_BC_SET_SA_SIN_MANDT is not an integral part of table/view EDOP.

They can be ignored as this fields are irrelevant in the information provided from the product for this table.

Once the consistency has been checked, click on the iconImage Modified to activate it.

Image Modified

Press OK as many times as necessary. 

During activation, the process will request a transport request.

...

Notes for each BC_SET activation

/EDGE/SII_BC_SET_SA_SIN_MANDT

During activation of BC_SET /EDGE/SII_BC_SET_SA_SIN_MANDT, the process will request a transport request.

To check that it has been activated successfully, the following tables must appear in the generated transport request:

    • /EDGE/
    EI
    • SII_
    IT
    • MP_
    CDDE
    • 000
    • /EDGE/SII_MP_
    000
    • 005
    • /EDGE/SII_MP
    _005
  • BALOBJ
  • EDOPROCSTEPV
  • EDOTYPEV
  • EDOPROCSTEPVERV
  • V_BALSUB
    • _014
    • /EDGE/SII_PRIORI
    • BALOBJ
    • EDOCOUNTRYTCH
    • EDOFILETYPEV
    • EDOPROCESSV
    • EDOSRCTYPEV
    • EDOTYPEV
    • TBE11
    • TMENU01
    • TMENU01R
    • TTREES
    • TTXOB
    • TVIMF
    • V_TVIMF
    • /EDGE/SII_CS001
    • /EDGE/SII_CS002
    • EDOPROCSTAFLAGV
    • EDOPROCSTEPV
    • TBE31
    • TMENU01T
    • TTXID
    • V_BALSUB
    EDOPROCFLAGASGV/EDGE/SII_PRI
    • EDOPROCSTEPVERV
    • EDOPROCFLAGASGV

Image Modified

/EDGE/SII_BC_SET_SA_CON_MANDT

During activation of BC_SET /EDGE/SII_BC_SET_SA_CON_MANDT, the next pop-up can appear:

Click on "Copy values" with no data in Company Code field.

...