Info | ||
---|---|---|
| ||
This issue is resolved in product version 1.7.5. with this version installed it is not necessary to make this adjustment. |
By mistake the Fallback classes of BAdIS for the new XML version 1.1 (product version 1.7.4) have been created with the Final flag marked. This means that they cannot be used as inheritance for other classes.
...
If the namespace is closed in the system, you cannot change an /edge/ standard object. The message that will come out is this:
To be able to edit this standard object go to transaction SE06 and press System Change Option:
...
Search for the namespace /EDGE/ which will be in "Not Modifiable":
Change it to "Modifiable" and save.
Return to class /EDGE/CL_SII_SII_MAPEOS_GEN_1_1 and press modify again. This time the message that will come out is as follows:
...