Versiones comparadas

Clave

  • Se ha añadido esta línea.
  • Se ha eliminado esta línea.
  • El formato se ha cambiado.

When the installation stops in the IMPORT_PROPER phase due to an error, the following screen will be displayed:

Image Added

Pressing button logs: Image Added will allow you to see the errors.

For SAPK-10002INTESII:

Image Added

If you extend the error log, the following will be read:

Image Added

For SAPK-10005INTESII:

Image Added

Image Added

To solve this error, two tables must be corrected manually. The tables are /EDGE/SII_MPT010 and /EDGE/SII_MPT014.


To do this, perform the following action in both tables.

Transaction SE11: Enter the name of a table /EDGE/SII_MPT010. Press Modify. If the next pop-up appears:

Image Added

Go to t-code SE06 and press "System  Change Option":

Image Added

Search /EDGE/ and set it as "Modifiable":

Image Added

This way, the table can be modified from the transaction SE11.

Once we can edit the table, we add the MANDT field in the first position and mark it as a key:

Image Added

Save. Select an order that will NOT be transported. Attempting to activate will result in an error because the object is blocked by the installation queue.

Carry out the same process with table /EDGE/SII_MPT014 so that it looks like this:

Image Added

The next step is to activate these two objects for the installation to detect the change. To do this, go to transaction SE38 and run report RADMASG0:

On the selection screen, click on the "Direct objects" button:

Image Added

In table name, select the button to enter several names and enter both entries with the names of the two tables:

Image Added

Execute the report. Check that no errors occur. If an error occurs, it is because the table needs to be converted. To do this, go to transaction SE14 and enter the name of the table and press Edit:

Image Added

On the next screen, click on "Activate and adapt database" with the save data option:

Image Added

After this adjustment, run report RADMASG0 again with the table that gave the error. The result should be satisfactory and the table should appear as active. (Check from the SE11 that both are active).

Resume installation at SAINT and continue with the process as normal.


Once the installation has been successfully completed, these two objects must be left in the correct version again. Therefore, when the complete installation in the SAINT has finished, recover the version that comes from the product in the last available version. This action can be followed at the following link: Retrieve product version for affected tables in the import of the installation.