Installation files
In this release two new support packages are released:
...
These files can be downloaded from the customer portal in the installation section, version 1.7.4, using software components:
Prerequisites
It is necessary to have the License component installed: 1.1.2.1 Installation of License Component BPCORE. It is enough to have the component installed to carry out the installation, it is not necessary to wait for the activation of the license.
...
Installation for SP5 TESII and SP4 TESIICNC.
Log in the system in EN, Client 000.
Once they have been loaded, press
Then select the TESII component.
The SPs to be installed will appear in green.
Press the green check and in the next pop up, press NO.
...
Once the process is finished, click on the queue confirmation icon.
BC_SETs activation
...
/EDGE/SII_BC_SET_SP5_SIN_MANDANT: It only needs to be activated in one client since its tables are not client-dependent.
/EDGE/SII_BC_SET_SP5_CON_MANDANT: It needs to be activated it in every available client because the data it contains is client-dependent.
...
To activate a BC_SET go to t-code SCPR20. Enter the name of BC_SET: /EDGE/SII_BC_SET_SP5_SIN_MANDANT.
Click on the Consistency Check icon and check that no errors occur.
This Warning may appear: Field TABNAME of set CE /EDGE/SII_BC_SET_SP5_SIN_MANDANT is not an integral part of table/view EDOTYPE. It can be ignored as this field is irrelevant in the information provided from the product for this table.
In this consistency check the BC_SET /EDGE/SII_BC_SET_SP5_SIN_MANDANT, may give an error.
This is due to the SAP version of this table. In product, the records in this table are defined by the key fields:
- PROCESS
- VERSION
- PROCESS_STEP
However, in different versions the key fields may have a non-key field as a second field:
This causes problems when entering BC_SET entries in this table.
If this is the case, and this error occurs in this BC_SET, proceed as follows.
Activate the BC_SET despite the error so that all other tables in this BC_SET are recorded in the system.
Then, enter the following entries manually in the view of the SM30 EDOPROCSTEPVERV:
Proc. edoc. | Process Description | Ver. | Process Step | Proc. Step Description |
---|---|---|---|---|
/EDGE/SIIL | Sistema Información Imp. Lotes | 2 | ||
/EDGE/SIIL | Sistema Información Imp. Lotes | 2 | ACCEPT | Accept Batch |
/EDGE/SIIL | Sistema Información Imp. Lotes | 2 | ACCEPT_ERR | Accept Batch with errors |
/EDGE/SIIL | Sistema Información Imp. Lotes | 2 | CORR_LOTE | Correct Batch |
/EDGE/SIIL | Sistema Información Imp. Lotes | 2 | CREATE | Create Batch |
/EDGE/SIIL | Sistema Información Imp. Lotes | 2 | DIS | Discard batch ECC |
/EDGE/SIIL | Sistema Información Imp. Lotes | 2 | DISMW_DIS | Discard batch MW+ECC |
/EDGE/SIIL | Sistema Información Imp. Lotes | 2 | ERROR_MW | Error in MW process |
/EDGE/SIIL | Sistema Información Imp. Lotes | 2 | GENXML_SEN | Generate XML and send to MW |
/EDGE/SIIL | Sistema Información Imp. Lotes | 2 | MAP_ERROR | Mapping error |
/EDGE/SIIL | Sistema Información Imp. Lotes | 2 | REJECT | Reject Batch |
/EDGE/SIIL | Sistema Información Imp. Lotes | 2 | REPROC_MW | Reprocessing Middleware |
/EDGE/SIIL | Sistema Información Imp. Lotes | 2 | RESEND | MW Forwarding Request |
/EDGE/SIIL | Sistema Información Imp. Lotes | 2 | SACAR_INT | Remove eDocs from eDocs Batch |
/EDGE/SIIL | Sistema Información Imp. Lotes | 2 | TIME_OUT | Time Out Error |
/EDGE/SIIL | Sistema Información Imp. Lotes | 2 | VXML_DISMW | Cancel XML&discard Batch MW+EC |
/EDGE/SIIL | Sistema Información Imp. Lotes | 2 | VXML_TCORR | Cancel XML and technical corre |
Insert these table entries into the transport request (workbench) that the BC_SET generates so that they are transported to all other environments.
Once the consistency has been checked, click on the icon to activate it.
Press OK as many times as necessary.
During activation, the process will request a transport request.
...
These entries identify the mapping classes to be used for the new version of XML with the new mappings 1.1. If these (standard) classes have been replaced for Z classes in the past, this table will have to be adjusted with the new classes of version 2 to fit the existing ones in version 1 of this table. For more information about this functionality, please visit the page 18.5. New mapping classes.
Manual actions after activation of BC_SETs
After activating the BC_SET it is necessary to check table /EDGE/SII_PRIORI. In a BC_SET, new entries are added for this table, but old entries that are now unusable are not deleted. To solve this problem, all entries that have no value in the "VersionXML" field (if any) must be deleted from this table. Thus, the only entries that must remain in this table are the following:
This process must be performed in all work environments so that the table is aligned and with the same records in all environments.